The Gauge pressure transmitter portfolio from ABB offers a broad variety of communication possibilities. Another highlight of our sensors is the measurement accuracy up to 0,04%.
 | 265GS | 265GC/265GG/265GJ/ 265GM/265GN | 265GR | 364PS |
 |  |  |  |  |
 |  |  |  |  |
| Accuracy | 0.04% | 0.04% | 0.04% | 0.06% |
 |  |  |  |  |
| Span Limits | 0.2...60000kPa;
0.8inH2O...8700psi | 6...60000kPa;
24 in H2O...
8700psi | 6...60000kPa;
25 in H2O...
8700psi | 0.16… 16000kPa; 0.65… 2320inH2O |
 |  |  |  |  |
| Communication | HART,
4-20 mA,
PA, FF | HART,
4-20 mA,
PA, FF | HART,
4-20 mA,
PA, FF | HART / 4-20 mA |
 |  |  |  |  |
| Description | Standard overload |  | Standard overload |  |
 |  |  |  |  |
 | 364GS | 364PR | 264GS | 264HF |
 |  |  |  |  |
 |  |  |  |  |
| Accuracy | 0.06% | 0.06% | 0.075% | 0.075% |
 |  |  |  |  |
| Span Limits | 0… 60000kPa; 50inH2O… 8700psi | 40mbar... 16000KPa; 16inH2O... 2320psi | 0.2...60000kPa;
0.8inH2O...8700psi | 0.65...160kPa;
2.6...642inH2O |
 |  |  |  |  |
| Communication | HART / 4-20 mA | HART / 4-20 mA | HART / 4-20 mA,
PA, FF | HART / 4-20 mA,
PA, FF |
 |  |  |  |  |
| Description |  | Gauge pressure with remote seal | Standard overload | High Overload
Fast Response |
 |  |  |  |  |
 | 264HS | 264HC | 264HR | 264PR |
 |  |  |  |  |
 |  |  |  |  |
| Accuracy | 0.075% | 0.075% | 0.075% | 0.075% |
 |  |  |  |  |
| Span Limits | 0,65…60000kPa;
2.6inH2O…8700psi | 1.1...16000kPa;
4.35inH2O...2320psi | 1.1...60000kPA;
4.35inH2O…8700psi | 0.546...16000kPa;
2.16inH2O...2320psi |
 |  |  |  |  |
| Communication | HART / 4-20 mA,
PA, FF | HART / 4-20 mA,
PA, FF | HART / 4-20 mA,
PA, FF | HART / 4-20 mA,
PA, FF |
 |  |  |  |  |
| Description | High overload |  |  |  |
 |  |  |  |  |
 | 264PF | 264PS | 264HD | 264HG |
 |  |  |  |  |
 |  |  |  |  |
| Accuracy | 0.075% | 0.075% | 0.06% | 0.075% |
 |  |  |  |  |
| Span Limits | 0.14...160kPa;
0.56...642inH2O | 0.05...16000kPa;
0.2inH2O...2320psi | 0.16...16000kPa;
0.65...2320inH2O | 1.1 to 8000 kPa;
4.35 inH2O to 1160 psi |
 |  |  |  |  |
| Communication | HART / 4-20 mA,
PA, FF | HART / 4-20 mA,
PA, FF | HART / 4-20 mA, | HART/4-20 mA, PA, FF |
 |  |  |  |  |
| Description | Fast Response |  |  |  |
 |  |  |  |  |
 | 264HP | 261GS | 261GC/261GG/ 261GJ/261GM/ 261GN | 261GR |
 |  |  |  |  |
 |  |  |  |  |
| Accuracy | 0.075% | 0.15% | 0.15% | 0.15% |
 |  |  |  |  |
| Span limits | 1.1 to 16000 kPa;
4.35 inH2O to 2320 psi | 0.3...60000kPa;
1.2inH2O...8700psi | 6...60000kPa;
24inH2O...
8700psi | 6...
60000kPa;
24inH2O...
8700psi |
 |  |  |  |  |
| Communication | HART/4-20 mA, PA, FF | HART / 4-20 mA | HART /
4-20 mA | HART / 4-20 mA |
 |  |  |  |  |
| Description |  | Standard overload
Compact Class | Standard overload, compact class, frontbonded diaphragms or direct mount seals | Standard overload
Compact Class
with remote seals |
 |  |  |  |  |