Conductivity Cells

Our broad range of conductivity cells encompasses three measuring techniques: 2-electrode cells for µS/cm ranges, 4 and 6 electrode sensors for mS/cm levels and non-contact, electrode-less sensors.
Multi-electrode and electrode-less (toroidal) sensors tend to be used for applications with aggressive chemicals or where there can be sensor coating or fouling.
Comprehensive mounting methods are available to suit the majority of process applications: insertion, flow-through, immersion and retractable.



2-Electrode Contacting Cells - Range 0 ... 10,000 µS/cm
High accuracy technique for trace conductivities from ultrapure water to industrial rinse waters. An alternating current is passed between two electrodes in contact with a solution. The transmitter converts the resultant potential difference into conductivity, concentration or specific resistance.


Table 1 of 3
AC211AC212AC213AC221
>>read more

>>read more>>read more
>>read more
Electrode MaterialCarbonCarbonCarbonStainless steel
Cell Constant0.1 or 1.00.1 or 1.00.1 or 1.00.01 or 0.1
Temperature100 °C (212 °F)100 °C (212 °F)90 °C (194 °F)*200 °C (392 °F)**
Pressure6.6 bar (100 psi)6.6 bar (100 psi)--20 bar (290 psi)
Submersion----10 m
(AC213/0)
--
Immersion----1 or 2 m
(AC213/1 & AC213/2)
--
Flow-through--1/2 in. BSP or NPT--3/8 in. BSP or NPT
Screw-in Insertion1 in. BSP or NPT----3/4 in. BSP or NPT
Retractable--------
Tri-Clamp Insertion--------
* AC213/1 & /2 only** When used with high temperature cable
Back >>


Table 2 of 3
22782085TB25TB254
>>read more>>read more>>read more>>read more
Analytical Conductivity Sensor
Electrode MaterialStainless steelStainless steelStainless steelStainless steel
Cell Constant0.050.05 or 0.10.01, 0.1 or 1.00.01, 0.1 or 1.0
Temperature130 °C (266 °F)110 °C (230 °F)175 °C (347 °F)100 °C (212 °F)
Pressure10.5 bar (150 psi)10.5 bar (150 psi)8.6 bar (125 psi)6.9 bar (100 psi)
Immersion---3/4 in. NPT
Flow-through----
Screw-in Insertion---1 in. NPT
Retractable-1-1/2 in. BSP or NPT--
Tri-Clamp Insertion2 in.-1-1/2 in., 2 in., 2-1/2 in., 3 in.-
Back >>


Table 3 of 3
TB26TB264TB27
>>read more>>read more>>read more
Analytical Conductivity Sensor
Electrode MaterialStainless steelStainless steelStainless steel
Cell Constant0.01, 0.1 or 1.00.01, 0.1 or 1.00.01, 0.1 or 1.0
Temperature200 °C (392 °F)200 °C (392 °F)200 °C (392 °F)
Pressure6.9 bar (100 psi)13.8 bar (200 psi)20.7 bar (300 psi)
Immersion1/2 in. NPT--
Flow-through-1/2 in. NPT-
Screw-in Insertion3/4 in. NPT--
Retractable1-1/2 in. NPT-1-1/2 in. NPT
Tri-Clamp Insertion---
Back >>


4-Electrode Contacting Cells - Range 0 ... 2,000 mS/cm
Auto-compensating technology for high level conductivity and concentration measurements in high-coating processes. Provides an alarm when cleaning is required.


Table 1 of 2
TB451TB454TB457TB461
>>read more>>read more>>read more>>read more
Electrode MaterialStainless steelStainless steelStainless steelStainless steel
Temperature140 °C (284 °F)100 °C (212 °F)175 °C (347 °F)200 °C (392 °F)
Pressure6.9 bar (100 psi)6.9 bar (100 psi)8.6 bar (125 psi)15.5 bar (225 psi)
Immersion-3/4 in. NPT-1/2 in. NPT
Flow-through----
Screw-in Insertion-1 in. NPT-3/4 in. NPT
Retractable--1-1/4 in. NPT
Tri-Clamp Insertion1 in. and 1-1/2 in.-1-1/2 in., 2 in., 2-1/2 in., 3 in.-
Back >>

Table 2 of 2
TB464TB468TB47
>>read more>>read more>>read more
Analytical Conductivity SensorAnalytical Conductivity Sensor
Electrode MaterialStainless steelHastelloy CStainless steel
Temperature200 °C (392 °F)Up to 140 °C (284 °F)200 °C (392 °F)
Pressure13.8 bar (200 psi)Up to 6.9 bar (100 psi) 20.7 bar (300 psi)
Immersion---
Flow-through1/2 in. NPT--
Screw-in Insertion-3/4 in. NPT-
Retractable-1 in. NPT1-1/4 in. NPT
Tri-Clamp Insertion---
Back >>

6-Electrode Contacting Cells - Range 0 ... 500 mS/cm
Auto-compensating technology for high level conductivity and concentration measurements in high-coating processes. Provides an alarm when cleaning is required.
222122412271
>>read more>>read more>>read more
Electrode MaterialCarbonCarbonCarbon
Temperature Sensor Pt1000Pt1000Direct contact Pt1000
Temperature100 °C (212 °F)100 °C (212 °F)100 °C (212 °F)
Pressure - 6.6 bar (100 psi)6.6 bar (100 psi)
Immersion0.9 m--
Flow-through-1/2 in. BSP or NPT-
Screw-in Insertion--1 in. BSP or NPT
Hygienic fittings--DIN 11851 or Tri-Clamp
Back >>

Electrodeless Sensors - Range 0 ... 2,000 mS/cm
Non-contact technique providing immunity to polarisation, oily fouling and non-conducting coatings until gross fouling occurs. Measurement of the magnitude of induced AC into a closed loop of solution using two embedded toroids.
TB4042TB4043
>>read more>>read more
Analytical Conductivity Sensor
Body MaterialPEEKPEEK
Temperature200 °C (392 °F)121°C (250 °F)
Pressure6.6 bar (100 psi)6.6 bar (100 psi)
Immersion3/4 in. NPT-
Flow-through--
Screw-in Insertion1-1/2 in. NPT-
Rectractable1-1/2 in. NPT-
Tri-Clamp Insertion-2 in.
Back >>



    • Rate this page
        Cancel
    • Share this page
    •   Cancel

    Your preferences:

    ABB contact for

    United Kingdom
    Service: Neil Ritchie
     

    Downloads

    View related documents and downloads for:
    seitp330 22c66425d4b54425c1256cd9003aaa11