Conductivity Analyzers

ABB conductivity analysers are designed to meet the most exacting requirements of our valued customers. The extensive range covers 2 and 4-wire analysers and single or dual-input devices.

Our hazardous area certifications embrace FM, CSA and CENELEC ATEX intrinsic safety. Instruments are available with HART, PROFIBUS PA or DP, and FOUNDATION Fieldbus communications capabilities.

    High accuracy technique for trace conductivities from ultrapure water to industrial rinse waters. An alternating current is passed between two electrodes in contact with a solution. The transmitter converts the resultant potential difference into conductivity, concentration or specific resistance.
    Traceable calibration instruments for WFI and PW processes in the Pharmaceutical Industry.
    Auto-compensating technology for high level conductivity and concentration measurements in high-coating processes.
    Non-contact technique providing immunity to polarisation, oily fouling and non-conducting coatings until gross fouling occurs. Measurement of the magnitude of induced AC into a closed loop of solution using two embedded toroids.

2-Electrode Contacting Cells - Range 0 to 10,000 µS/cm (Table 1 of 2)
AX410AX411AX413AX416
>>read more>>read more>>read more>>read more
Input 1µS/cmµS/cmµS/cmµS/cm
Input 2-µS/cmmS/cmpH
MountingPanel, Wall, PipePanel, Wall, PipePanel, Wall, PipePanel, Wall, Pipe
Power Supply4-wire AC & 24 V DC4-wire AC & 24 V DC4-wire AC & 24 V DC4-wire AC & 24 V DC
Current Outputs2 or 42 or 42 or 42 or 4
Relay Outputs3 or 53 or 53 or 53 or 5
PID ControlYes---
Hazardous ApprovalATEX Type N (pending)
FM / CSA Class 1 Div 2 (pending)
ATEX Type N (pending)
FM / CSA Class 1 Div 2 (pending)
ATEX Type N (pending)
FM / CSA Class 1 Div 2 (pending)
ATEX Type N (pending)
FM / CSA Class 1 Div 2 (pending)
Communications4 ... 20 mA
PROFIBUS DP
4 ... 20 mA
PROFIBUS DP
4 ... 20 mA
PROFIBUS DP
4 ... 20 mA
PROFIBUS DP
>>back


2-Electrode Contacting Cells - Range 0 to 10,000 µS/cm (Table 2 of 2)
46204625TB82TE*TB84TE*
>>read more


>>read more


>>read more


>>read more


Input 1µS/cmµS/cmµS/cmµS/cm
Input 2----
MountingWall, PipePanelPanel, Wall, PipePanel, Wall, Pipe
Power Supply4-wire AC4-wire AC 2-wire 24 V DC4-wire AC
Communications4 ... 20 mA, MODBUS4 ... 20 mA, MODBUS4 .. 20 mA, HART, FOUNDATION Fieldbus,
PROFIBUS PA
4 ... 20 mA
* Range 0 - 20,000 µS/cm
>>back


2-Electrode Contacting Cells - United States Pharmacopœia <645>
AX450AX45546234628
>>read more>>read more>>read more>>read more
Input 1µS/cmµS/cmµS/cmµS/cm
Input 2-µS/cm--
Mounting Panel, Wall, PipePanel, Wall, PipePanel, PipePanel
Power Supply4-wire AC4-wire AC4-wire AC4-wire AC
Communications4 ... 20 mA
PROFIBUS DP
4 ... 20 mA
PROFIBUS DP
4 ... 20 mA
MODBUS
4 ... 20 mA
MODBUS
>>back


4-Electrode Contacting Cells - Range 0 to 2,000 mS/cm (Table 1 of 2)
AX430AX433AX436
>>read more>>read more>>read more
Input 1mS/cmmS/cmmS/cm
Input 2mS/cmpH/ORP
MountingPanel, Wall, PipePanel, Wall, PipePanel, Wall, Pipe
Power Supply 4-wire AC & 24 V DC 4-wire AC & 24 V DC 4-wire AC & 24 V DC
Current Outputs2 or 42 or 42 or 4
Relay Outputs3 or 53 or 53 or 5
PID ControlYes--
Hazardous ApprovalATEX Type N (pending)
FM / CSA Class 1 Div 2 (pending)
ATEX Type N (pending)
FM / CSA Class 1 Div 2 (pending)
ATEX Type N (pending)
FM / CSA Class 1 Div 2 (pending)
Communications4 ... 20 mA
PROFIBUS DP
4 ... 20 mA
PROFIBUS DP
4 ... 20 mA
PROFIBUS DP
>>back


4- or 6- Electrode Contacting Cells - Range 0 to 2,000 mS/cm (Table 2 of 2)
4621**4626**TB82EC**TB84EC**
>>read more>>read more>>read more>>read more
Method6-electrode**6-electrode**4-electrode4-electrode
Input 1mS/cmmS/cmmS/cmmS/cm
Input 2----
Power Supply4-wire AC4-wire AC2-wire 24 V DC4-wire AC
Communications4 ... 20 mA, MODBUS4 ... 20 mA, MODBUS4 ... 20 mA, HART, FOUNDATION Fieldbus,
PROFIBUS PA
4 ... 20 mA
MountingWall, PipePanelPanel, Wall, PipePanel, Wall, Pipe
** Range 0 - 400 mS/cm
>>back


Electrodeless sensors - Range 0 to 2,000 mS/cm
TB82TC**TB84TC**
>>read more>>read more
MethodElectrodelessElectrodeless
Input 1mS/cmmS/cm
Input 2--
Power Supply2-wire 24 V DC4-wire AC
Communications4 ... 20 mA, HART,
FOUNDATION Fieldbus,
PROFIBUS PA
4 ... 20 mA
Mounting Panel, Wall, PipePanel, Wall, Pipe